1ph-1ph | 3ph-3ph
Inverter
TECHNICAL SPECIFICATIONS
1ph-1ph
| PRODUCT TYPE : |
SINE WAVE INVERTERS |
| RATING : |
1KVA
to 50KVA |
| Mains Input : 1 phase |
UPS
Output: 1 phase |
INPUT
| Voltage
: |
230 v
ac , single phase, |
| Range
: |
+ / -
20% |
| Frequency
: |
50Hz
+/- 5Hz |
CHARGER
| Type : |
SCR
controlled. |
| Regulation : |
Within
2%. |
| Efficiency : |
Better
than 90%. |
OUTPUT
| Voltage : |
230v
ac , single phase |
| Voltage regulation : |
+/-
1% |
| Frequency : |
50Hz/60Hz/400Hz +/- 0.05% (Crystal
control) |
| Distortion : |
Less
than 3 % T.H.D. on linear load. |
| Waveform : |
Pure
sine wave |
| Technique : |
Sine
weighted PWM, using micro controller ( high frequency
switching, IGBT based inverter) |
| Power factor : |
0.7
lag to unity. |
| Power rating : |
1KVA
to 50KVA , |
| Inverter efficiency : |
Typically 90%. |
| Crest factor : |
3:1 |
| Transient response : |
Better
than 4% for 100% instant load change. Recovery time: 20
msecs |
| Overload : |
More
than 150% for 5
secs. |
| PROTECTIONS (electronic protections) : |
1. Low battery. 2. Output over/under voltage. 3.
Output overload/ short circuit. |
| MANUAL BYPASS SWITCH |
| shall be provided as a common
feature. |
....................................................................................................................................................Top........
| PRODUCT
TYPE : |
SINE WAVE INVERTERS |
| RATING
: |
6KVA
to 150KVA |
| Mains
Input : 3 phase |
UPS
Output: 3 phase |
INPUT
| Voltage : |
415
v ac , three phase, 4 wire |
| Range : |
+
/ - 15% |
| Frequency : |
50Hz
+/- 5Hz |
CHARGER
| Type
: |
SCR
controlled. |
| Regulation
: |
Within
2%. |
| Efficiency
: |
Better
than 90%. |
OUTPUT
| Voltage
: |
400v
ac, three phase, 4 wire
(each phase is independently controlled) |
| Voltage
regulation : |
+/-
2% per phase |
| Frequency
: |
50Hz/60Hz/400Hz
+/- 0.05% (Crystal control) |
| Distortion
: |
Less
than 3 % T.H.D. on linear load ( between phase to
neutral). |
| Waveform
: |
Pure
sine wave |
| Technique
: |
Sine
weighted PWM, using micro controller
( high frequency switching, IGBT based inverter) |
| Power
factor : |
0.7
lag to unity. |
| Power
rating : |
6KVA
to 150KVA , |
| Inverter
efficiency : |
Typically
90%. |
| Crest
factor : |
3:1 |
| Transient
response : |
Better
than 4% for 100% instant load change.
Recovery time: 20 msecs |
| Overload
: |
More
than 150% for 5 secs. |
| PROTECTIONS
(electronic protections) : |
1.
Low battery.
2. Output over/under voltage.
3. Output overload/ short circuit. |
| MANUAL
BYPASS SWITCH |
| shall
be provided as a common feature. |
................................................................................................................................................................
Top
|
Back
| UPS Systems (1ph-1ph,
3ph-1ph,
3ph-3ph)
| Contact
|
|